Chips → conveyor at the machine
Hinged-belt, scraper, magnetic or belt conveyors, chosen by chip type and volume. They remove chips from the pan continuously and discharge them into the hopper without stopping the machine.
Chips pile up in the machine pan and fines recirculate with the coolant, while way oil contaminates it. The result: stops to clear chips by hand, premature tool wear, damaged pumps and spindles, and frequent coolant changes. A chip conveyor on each machine, or a centralized line for the whole shop, plus coolant filtration by belt filter, magnetic separation and skimmer. Both are sized together around the chip type, the coolant, the flow rate and the layout. The machine no longer stops for chips, tools last longer and the coolant is reused several times over before disposal. Chips out, clean coolant back. Engineered on the plant floor, built in-house by Trans-Fil.
Chip conveyors and coolant filtration for CNC lathes and machining centers, engineered as one system: chips leave the machine and coolant comes back clean. Designed and built in-house by Trans-Fil since 1989. A plant survey precedes every technical proposal.
Typical ranges in installations with adequate treatment. Figures for each plant are established during the survey.
Chips pile up in the machine pan and fines recirculate with the coolant, while way oil contaminates it. The result: stops to clear chips by hand, premature tool wear, damaged pumps and spindles, and frequent coolant changes.
A chip conveyor on each machine, or a centralized line for the whole shop, plus coolant filtration by belt filter, magnetic separation and skimmer. Both are sized together around the chip type, the coolant, the flow rate and the layout.
The machine no longer stops for chips, tools last longer and the coolant is reused several times over before disposal.
The conveyor takes chips out of the machine, and the coolant that drains from them goes through the filter before it returns. That is why they are engineered together: a conveyor that carries fines overloads the filter, and a filter without a conveyor fills up with chips.
Hinged-belt, scraper, magnetic or belt conveyors, chosen by chip type and volume. They remove chips from the pan continuously and discharge them into the hopper without stopping the machine.
A line that carries chips from the whole shop floor to a single discharge point. It connects dozens of machine tools to one circuit and removes manual handling between stations.
The magnetic separator removes fine ferrous particles and the belt filter retains the rest by gravity, on paper or textile media. The media advances automatically with the bath level and discharges dry residue.
The skimmer removes the way oil floating on the tank, the main cause of odor and early disposal of the emulsion. A central coolant system can feed several machines at stable flow and temperature.
Conveyor and filter are sized as one system: the same engineering team decides where the chips go and where the coolant goes.
Hinged belt for long or stringy chips, scraper for short chips and fines, magnetic for small ferrous chips. The choice is made on the actual chips of each process.
Discharge height, chip pan and tank are measured on site, and every unit is validated in 3D before it is built.
Control panels are designed for 480 V / 60 Hz, or your plant’s own supply, and built to the electrical standard you specify.
Trans-Fil technicians travel to your plant for installation and commissioning. After start-up, the same engineering team supports you remotely.
Since 1989, with over 120 industrial customers in 14 countries, including the United States. Units installed in the 1990s are still in operation.
Automotive, machine-tool, steel and tube plants in 14 countries.
Tell us which machines you run, what chips they produce and which coolant you use. A technical advisor replies within 24 business hours with a defined next step.
Francisco de Arteaga 2895, Córdoba, Argentina
31°24′17″S · 64°11′31″W
Yes. Conveyor and filter are sized around the machine, the chips and the coolant, not the brand. During the survey we measure the discharge height, the chip pan and the tank of each machine.
It depends on chip shape and material: hinged belt for long or stringy chips, scraper for short chips and fines, magnetic for small ferrous chips. It is often combined with a filter for the coolant that drains from the chips.
Yes. A centralized line takes chips from the whole shop floor to a single discharge point, and a central coolant system feeds several machines with filtered coolant at stable flow and temperature.
With adequate treatment, coolant service life increases by a factor of 2 to 4 and tool life rises by 10% to 30%, while chip conveying removes stops for manual clean-out. These are typical ranges: figures for each plant are established during the survey.
Yes. The panel is designed for 480 V / 60 Hz, or your plant’s own supply, and built to the electrical standard you specify.
Both are quoted per project, together with the technical proposal. They depend on the scope and on the destination.
Chips out, clean coolant back. Engineered on the plant floor, built in-house by Trans-Fil.
Request a plant survey